UNIMAG 1800 AC

 BASIC DESCRIPTION: 
  • clamping length between the poles 1800 mm, stroke of pneumatic valve 25 mm, mechanically poles adjustment
  • stepless current setting
  • current (circulary) AC magnetization, max. current 3200 Arms (effective)
  • manually movable AC coil ∅ 420 mm
  • signalling deviation ± 10% of preseted current value
  • timers for magnetisation and wetting 2,5 – 30 sec
  • AC demagnetization by decreasing curve (2 sec.)
  • duty cycle (intermitent) 30 %
  • manual/automatic process control
  • electropneumatic switching between lengthwise and circulary magnetization
  • ink system with 40 litres stainless steel reservoir, pump 90 VA, hand hose spraying
  • weight of tested parts up to 300 kg
  • feeding 3 + PE 400 V – 50 Hz, power consumption 50 kVA

 

OPTION: 
  • added braces for 1000 kg weight of tested part
  • manually rotation of the tested part
  • dark cabine, UV lamps, UV meters, light meters (Luxmeters), Gauss/Tesla meters, MTU gauges, Berthold’s gauges, centrifuge tubes
  • coils / tunnels for demagnetization, conveyors

 